The store will not work correctly when cookies are disabled.
We Accept POs from Fortune 1000 Companies, Government Agencies, Universities, Schools and Colleges
C9200L-48P-4X-E - Cisco Catalyst 9200L-48P POE+ 48 x Ports 10/100/1000Base-T 4 x SFP Layer 3 Manage Gigabit Ethernet Switch
C9200L-48P-4X-E - Cisco Catalyst 9200L-48P POE+ 48 x Ports 10/100/1000Base-T 4 x SFP Layer 3 Manage Gigabit Ethernet Switch
Manufacturer: Cisco
Mfr. Part#:: C9200L-48P-4X-E
Item Overview
Availability:
In Stock
Anywhere
Delivery Option
Free Ground in UAE
2 to 6 days (Varies by location)
Return & Warranty
30 days return
Get the best Cisco switches with Cisco - C9200L-48P-4X-E - Switch Catalyst 9200, it will provide you better connectivity and durability
More Information
IE-2000U-16TC-G-X Specification
IE-2000U-16TC-G-X Specification
|
Total Ports
|
20
|
RJ45 Ports
|
16 FE
|
Combo Ports
|
2 GE + 2 FE
|
Software
|
LAN Base
|
IEEE 1588
|
Yes
|
PRP
|
Yes
|
Dimensions (H x W x D), Including DIN Rail
|
5.1 x 5.0 x 5.26 in (130 x 127 x 134 mm)
|
Weight
|
4.35 lbs (1.97 kg)
|
Hardware
|
? 256 MB DRAM with ECC memory
? 1 GB removable SD flash memory card (CG swap drive) ? (128MB space available)
? Mini-USB connector
|
Alarm
|
? Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max
|
Power Supply
|
? Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum
? Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC
|
Power Consumption
|
20-port models: 13-20 W
|
Substation Compliance
|
? IEC 61850-3
? IEEE1613
|
Hazardous Location
|
? ANSI/ISA 12.12.01 (Class 1, Div 2 A-D) (requires cabinet enclosure)
? UL/CSA 60079-0, -15 (Class 1, Zone 2, group II gases, requires cabinet enclosure)
? EN 60079-0, -15 ATEX certification (Class I, Zone 2, Group II gases, requires cabinet enclosure)
? IEC 60079-0, -15 (Class I Zone 2, Group II gases, requires cabinet enclosure)
? CSA 213
|
Industrial Control Safety
|
? UL508
? CSA C22.2 No. 142
|
EMC Interface Immunity
|
? EN 55024 (CISPR 24)
? AS/NZS CISPR 24
? KN 24
? IEC61000-4-2 (Criteria A - Class 2)
? IEC61000-4-3/ENV50204 (Criteria A)
? IEC61000-4-4 (Criteria A/Criteria B)
? IEC61000-4-5 (Criteria B)
? IEC61000-4-6 (Criteria A)
|
Standard Electromagnetic Emissions Certifications
|
? FCC Part 15 Class A
? EN 55022 Class A (CISPR22 Class A)
? ICES-003 Class A
? EN 300 386
? VCCI Class A
? AS/NZS CISPR22 Class A
? CNS 13438 Class A
? KN 22 Class A CE Marking
|
Standard Safety Certifications
|
? UL 60950-1
? CSA 60950-1
? EN 60950-1
? IEC 60950-1, CB report and certificate with all national differences
|
Operating Environment
|
? Operating Temperature: -40C to +75C
? -40C to +70C (Vented Enclosure ? 40 LFM Air Flow)
? -40C to +60C (Sealed Enclosure ? 0 LFM Air Flow)
? -34C to +75C (Fan or Blower equipped Enclosure ? 200 LFM Air Flow)
? -40 to +85C (IEC 60068-2-2 Environmental Type testing - 100 hours)
? Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), de-rate maximum operating temperature per IEEE 1613-2009:
? Relative humidity: 5% to 95% non-condensing
|
Storage Environment
|
? Temperature: -50? C to +85? C
? Altitude: 15,100 ft (4600 m)
|
Warranty
|
? Five-year limited warranty on all IE-2000U HW PIDs
|
Mean Time Between Failure (MTBF)
|
? 535,190 Hours
|
Protection Class Code
|
? IP30 per EN60529
|
|
Condition |
Refurbished |