Brocade 16Gb SAN Switch for HPE BladeSystem c-Class Specification
|
Fibre Channel ports
|
16 Internal (downlink) ports; 12 External (uplink) ports - universal (E, F, N, D) ports 16/16c SAN Switch model: (16) 16 Gb ports in any internal/external port combination enabled 16/28c SAN Switch models: 16 internal 16Gb ports and 12 external 16 Gb auto-sensing ports enabled
|
Performance
|
16 Gbps line speed, full duplex
|
Switch core
|
Non-blocking
|
Fabric latency
|
700 nSec. Latency increases as input port speed is lower than the output port speed.
|
Maximum frame size
|
2112-byte payload
|
Classes of service
|
Class 2, Class 3, Class F (inter-switch frames)
|
Port types
|
D_Port (Diagnostic port), E_Port, F_Port; optional port type control Brocade Access Gateway mode: F_Port and NPIV-enabled N_Port
|
Data traffic types
|
Fabric switches supporting unicast
|
Media types
|
Hot-pluggable, B-Series Branded Small Form Factor Pluggable (SFP), LC connector; Short-Wave Laser (SWL), Long-Wave Laser (LWL); Extended Long-Wave Laser (ELWL); distance depends on fiber-optic cable and port speed. Supports SFP (4/2/1 Gbit/sec) and/or SFP+ (8/4/2 Gbit/sec) optical transceivers.
|
Laser
|
Short-wave, long-wave, and extended long wave laser transceivers (SFP's) are supported
|
Fabric services
|
Simple Name Server, Registered State Change Notification (RSCN). Includes Advanced WebTools Enhanced group Management and Advanced Zoning. Optional fabric services include: Adaptive Networking, Fabric Watch, ISL Trunking, Advanced Performance Monitoring, and Extended Fabrics.
|
Options
|
SFP media, port upgradeable licensing, advanced management software licensing
|
Supported software
|
Telnet, SNMP (FE MIB, FC Management MIB), HPE Systems Insight Manager, HPE Storage Essentials, HPE Onboard Administrator for BladeSystem, Advanced WebTools, Enhanced Group Management, , Advanced Zoning, SAN Network Advisor, Fabric Watch, and Advanced Performance Monitoring
|
Management access
|
WebTools, SMI-s provider, SNMP, Telnet, and Secure Telnet
|
Diagnostics
|
Cable diagnostic (D_Port), including electrical/optical loopback, link traffic/latency/distance
|
Dimensions
|
Depth
|
10.57 in.
|
Height
|
1.1 in.
|
Width
|
7.59 in.
|
Weight
|
Approx. 3.3 lb - without media
|
Environment
|
System Inlet Temperature
|
Operating
|
10? to 35?C (50? to 95?F) at sea level with an altitude derating of 1.0?C per every 305m (1.8?F per every 1000ft) above sea level to a maximum of 3050m (10,000ft), no direct sustained sunlight. Maximum rate of change is 10?C/Hr (18?F/Hr ). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30?C (86?F).
|
Non-operating
|
-30? to 60?C (-22? to 140?F). Maximum rate of change is 20?C/Hr (36?F/Hr).
|
Relative Humidity
|
Operating
|
10 to 90% relative humidity (Rh), 28?C (82.4?F) maximum wet bulb temperature, non-condensing.
|
Non-operating
|
5 to 95% relative humidity (Rh), 38.7?C (101.7?F) maximum wet bulb temperature, non-condensing.
|
Altitude
|
Operating
|
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
|
Non-operating
|
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
|
Vibration
|
Operating
|
1 G, 10-500 Hz, 60 minutes per axis
|
Non-operating
|
2 G, 10-500 Hz, 30 minutes
|
Shock
|
Operating
|
Half-sine-wave shock, 40 G, 2 ms duration, in each direction of three mutually perpendicular axes.
|
Non-operating
|
Half-sine-wave shock, 140 G, 2 ms duration, in each direction of three mutually perpendicular axes; and square-wave shock up to 80 G, 180 inches/s velocity change, in each direction of three mutually perpendicular axes.
|